Items | Technical Parameters | Remarks |
Operating temp. | -40-85ºC | Working for long time |
Nominal output power | 40KW | Support single phase input 6.6KW |
Input voltage range | Three phase 304-456VAC (L-L voltage,three phases four lines) |
single phase input: 175-265VAC |
Output voltage range | 400-650VDC | |
Max output current | 85A | single phase input:14A |
Auxiliary power | 9-32VDC | VCC |
Efficiency | ≥94% | @Nominal voltage |
Voltage accuracy | ±1% | |
Current accuracy | ±3% | |
Low voltage wake-up | 12/24Vdc&200mAmax(WAKE_UP signal) | Wake up BMS/VCU |
Wake-up method | CAN/AC/CC/CP | Support reserve charging function |
CAN communication | CAN-BUS | |
Static current | ≤2mA | Sleep mode/Battery current consumption under stop status |
EMC standard | GBT 18387: 2008,EN 55022 | |
Protections | Input OVP/UVP, output OVP/UVP,OTP, OCP, output short-circuit protection, CAN communication breakdown protection |